Status messages

When you run the self test, one or more of the following messages display. Messages display on the Diagnostics tab of the BARR/CHANNEL-OUT utility.

Message

Description

Loopback Test Passed

The adapter passed all diagnostics, including the loopback tests.

Loopback Failed: Address Alignment

The adapter was not found at the specified base address.

Loopback Failed: DMA

The bus master DMA logic is not working properly or there is a DMA conflict with some other hardware device.

Loopback Failed: IRQ

The interrupt logic on the adapter is not working properly or there is an IRQ conflict with some other hardware device.

Loopback Failed: Loopback Plug Missing

The test plugs were not detected because they are not installed or they are installed incorrectly.

Loopback Failed: BUS

The test plugs were detected, but a problem exists with one or more of the bus lines.

Loopback Failed: TAG

The test plugs were detected, but a problem exists with one or more of the tag lines.

Loopback Failed: Oscillator Error (0x100)

An oscillator on the adapter is not working properly. The adapter must be replaced.

20 MHz Oscillator Error (0x31)

An oscillator on the adapter is not working properly. The adapter must be replaced.

30 MHz Oscillator Error (0x32)

An oscillator on the adapter is not working properly. The adapter must be replaced.