Sample PU definitions

BARR/SPOOL

The following are sample VTAM PU definitions for a BARR/CHANNEL for SNA device, a Barr T1-SYNC for SNA device, an MSDLC(802.2) device, and an Enterprise Extender (IP-DLC) device.

See also:


Sample VTAM PU definition for a BARR/CHANNEL for SNA device

00009

*

 

 

000010

 

VBUILD TYPE=LOCAL

 

000011

LB102PU

PU CUADDR=E41,DISCNT=NO,

+

000012

 

ISTATUS=ACTIVE,

+

000013

 

DLOGMOD=D4A32XX3,

+

000014

 

MODETAB=DEFMODE,

+

000015

 

USSTAB=BARRTAB,

+

000016

 

MAXBFRU=48,

+

000017

 

PUTYPE=2,

+

000018

 

VPACING=7,

+

000019

 

PACING=7

 

000020

*

 

 

000021

*

 

 

000022

LB102A00

LU LOCADDR=0,USSTAB=,DLOGMOD=#INTER

 

000023

LB102P01

LU LOCADDR=1,USSTAB=,DLOGMOD=IBM3820

 

000024

LB102P02

LU LOCADDR=2

 

000025

LB102N03

LU LOCADDR=3,USSTAB=,DLOGMOD=BARRMOD

 

000026

LB102N04

LU LOCADDR=4,USSTAB=,DLOGMOD=BARRMOD

 

000027

LB102N05

LU LOCADDR=5,USSTAB=

 

000028

LB102N06

LU LOCADDR=6,USSTAB=

 

000029

LB102N07

LU LOCADDR=7,USSTAB=

 

000030

LB102N08

LU LOCADDR=8,USSTAB=

 

000031

LB102N09

LU LOCADDR=9,USSTAB=

 

000032

LB102N10

LU LOCADDR=10,USSTAB=

 

Sample VTAM PU definition for a Barr T1-SYNC for SNA device

The following is a sample PU definition for SDLC Acronym for Synchronous Data Link Control. A low-level communications protocol for synchronous communications.-attached 3174 cluster controller.

000003

 

VBUILD

TYPE=SWNET

 

000004

RMT1PU

PU

ADDR=01,

+

000005

 

PUTYPE=2,

 

+

000006

 

IDBLK=03D,

 

+

000007

 

IDNUM=12345,

 

+

000008

 

MAXDATA=1033,

 

+

000009

 

MAXOUT=7,

 

+

000010

 

PASSLIM=7,

 

+

000011

 

PACING=7,

 

+

000012

 

DISCNT=NO,

 

+

000013

 

USSTAB=,

 

+

000014

 

MODETAB=DEFMODE,

 

+

000015

 

VPACING=7

 

 

000016

*

 

 

 

000017

**

DIAL

DIALNO=00004000DDDD0004

 

000018

*

 

 

 

000019

RMT1LU0

LU

LOCADDR=0,DLOGMOD=#INTER,USSTAB=

 

000020

RMT1LU1

LU

LOCADDR=1

 

000021

RMT1LU2

LU

LOCADDR=2

 

000022

RMT1LU3

LU

LOCADDR=3

 

000023

RMT1LU4

LU

LOCADDR=4

 

000024

RMT1LU5

LU

LOCADDR=5

 

000025

RMT1LU6

LU

LOCADDR=6

 

000026

RMT1LU7

LU

LOCADDR=7

 

000027

RMT1LU8

LU

LOCADDR=8

 

000028

RMT1LU9

LU

LOCADDR=9

 

000029

RMT1LU10

LU

LOCADDR=10

 

000030

RMT1LU11

LU

LOCADDR=11

 

Sample VTAM PU definition for an MSDLC (802.2) or Enterprise Extender (IP-DLC) device

000010

*

 

 

000020

*

SWITCHED MAJOR NODE FOR TOKEN RING

 

000021

*

OR ETHERNET

 

000022

*

 

 

000023

*

NOTE: MAXDATA FOR TOKENRING SHOULD BE SET TO 4096.

 

000024

*

MAXDATA FOR ETHERNET MUST BE SET NO LARGER THAN 1490.

 

000025

*

 

 

000026

*

 

 

000027

LANETSWA

VBUILD TYPE=SWNET,MAXGRP=32,MAXNO=32

 

000028

*

DISCNT=NO,

 

000029

PB101PU

PU ADDR=01,PUTYPE=2,MAXPATH=4,ANS=CONT,DLOGMOD=D4A32XX3,

+

000030

 

ISTATUS=ACTIVE,MAXDATA=1490,IRETRY=YES,MAXOUT=7,

+

000040

 

PASSLIM=7,IDBLK=05D,IDNUM=FFFFF,MODETAB=DEFMODE,

+

000050

 

USSTAB=BARRTAB,PACING=7,VPACING=7

 

000060

*

 

 

000070

 

PATH DIALNO=0000400031745100,GRPNM=GROUP1

 

000080

*

 

 

000090

TB101A00

LU LOCADDR=0,USSTAB=,DLOGMOD=#INTER

 

000100

TB101P01

LU LOCADDR=1,USSTAB=,DLOGMOD=IBM3820

 

000200

TB101P02

LU LOCADDR=2

 

000300

TB101N03

LU LOCADDR=3,USSTAB=,DLOGMOD=BARRMOD

 

000400

TB101N04

LU LOCADDR=4,USSTAB=

 

000500

TB101N05

LU LOCADDR=5,USSTAB=

 

000600

TB101N06

LU LOCADDR=6,USSTAB=

 

000700

TB101N07

LU LOCADDR=7,USSTAB=

 

000800

TB101N08

LU LOCADDR=8,USSTAB=

 

000900

TB101N09

LU LOCADDR=9,USSTAB=