Troubleshooting: Configuring BARR/RJE

BARR/RJE

This topic contains solutions to common problems that you might experience when configuring BARR/RJE.

See also:


Unable to select an adapter

Cause: The BARR RJE service is currently started. The BARR RJE service must be stopped before you can select an adapter from the 802.2 Link tab or the SDLC Link tab.

Solution: Stop the BARR RJE service, and then try again.

Top

Host rejects logon data for the LU

Cause: The logon data in the RJE Configuration Utility is set incorrectly.

Solution: On the RJE Configuration Utility's RJE Description tab, from the Logon type drop-down list, select your appropriate logon type. Type the correct information in the Logon data box. Make sure that your new logon data matches what your host is expecting you to send. The host's rejection will usually occur for every LU that attempts to log on to JES.

Top

NCP definition does not match VTAM PU definition

Cause: The VTAM PU definition specifies more LUs than the NCP MAXLU parameter.

Solution: Ask the host programmer to configure the MAXLU parameter in the NCP definition to match the number of LUs defined in the VTAM PU definition. For more information, see the Communication link parameters topic.

Top

SYNC adapter fails loopback test

Cause: A possible hardware conflict exists, involving DMA Acronym for direct memory access..

Solution: Change the IRQ Acronym for interrupt request. setting and/or DMA level setting until you find a successful combination. If no combination of settings will pass the loopback test, you may either have bad hardware or a computer that does not support DMA.

Top

Cannot connect to host using Hayes Optima 33.6 modem

Cause: The Hayes Optima 33.6 modem does not work well with the AT Modem type selection.

Solution: On the RJE Configuration Utility's SDLC Connection Configuration dialog box, set the modem type to Not autodial and then store the phone number internally in the modem. This will set the modem to automatically dial the number when it senses the DTR Acronym for Data Terminal Ready. signal from the software. Your modem manual describes how to enable this feature. This problem does not occur with the Hayes Optima 56K or 28.8K modem.

Top

High speed transmission errors on SME cables using Barr adapters

Cause: The data rate might be set incorrectly.

Solution: On the RJE Configuration Utility's Link tab, verify the data rate setting.

In addition, you must check the SME cable length. Depending on the cable length and quality, you may be experiencing signal degradation. Try a shorter cable if possible, or purchase V.35 line drivers from a third party vendor, such as Black Box Corporation.

See also: Configuring the communication link

Top

Cannot connect to VPS host

Cause: RJE is not enabled in the VPS definition.

Solution: Ask the host programmer to set the RJE=YES parameter on the VPS definition.

Top

Problem with the host's LU definitions

Cause: The BARR/RJE LUs are not defined as the correct type or there are not enough LUs defined for what RJE is requesting.

Solution: Make sure enough LUs are defined and that they are the correct type. BARR/RJE LUs are defined on the host as RJE type, not 3270. LUs in VTAM should start at LOCADDR=2. A 10082007 Sense Code message indicates data truncation. For more information, see the Configuring VTAM and Communication link parameters topics.

LUs defined in VTAM should look similar to the definitions below.

luname02 LU

LOCADDR=2,BATCH=YES

luname03 LU

LOCADDR=3,BATCH=YES

Use the LU macro formula to calculate the number of LUs you need.

Check the communication settings, especially MAXOUT and MAXDATA, to make sure they match the settings at the host.

Top